The internal fluid mechanics losses generated between the blade plenum chamber and a reference point located just downstream of the trailing edge are investigated for a turbine blade trailing edge cooling system. The discharge coefficient Cd is presented as a function of the free stream Reynolds number, cut-back length, spanwise rib spacing and chordwise rib length. The results are presented in a wide range of coolant to free stream mass flow rate ratios. The losses from the cooling system show strong free stream Reynolds number dependency especially at low ejection rates when they are correlated against the coolant to free stream pressure ratio. However, when Cd is correlated against a coolant to free stream mass flow rate ratio, the Reynolds number dependency is eliminated. The current data clearly shows that internal viscous losses due to varying rib lengths do not differ significantly. The interaction of the external wall jet in the cut-back region with the free stream fluid is also a strong contributor to the losses. Since the discharge coefficients do not have Reynolds number dependency at high ejection rates, Cd experiments can be performed at a low free stream Reynolds number. Running a discharge coefficient experiment at low Reynolds number (or even in still air) will sufficiently define the high blowing rate portion of the curve. This approach is extremely time efficient and economical in finding worst possible Cd value for a given trailing edge coolant system.
Skip Nav Destination
ASME Turbo Expo 2000: Power for Land, Sea, and Air
May 8–11, 2000
Munich, Germany
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-7856-9
PROCEEDINGS PAPER
Aerodynamic Loss Characteristics of a Turbine Blade With Trailing Edge Coolant Ejection: Part 1 — Effect of Cut-Back Length, Spanwise Rib Spacing, Free Stream Reynolds Number and Chordwise Rib Length on Discharge Coefficients
Oğuz Uzol,
Oğuz Uzol
The Pennsylvania State University, University Park, PA
Search for other works by this author on:
Cengiz Camcı,
Cengiz Camcı
The Pennsylvania State University, University Park, PA
Search for other works by this author on:
Boris Glezer
Boris Glezer
Solar Turbines Inc., San Diego, CA
Search for other works by this author on:
Oğuz Uzol
The Pennsylvania State University, University Park, PA
Cengiz Camcı
The Pennsylvania State University, University Park, PA
Boris Glezer
Solar Turbines Inc., San Diego, CA
Paper No:
2000-GT-0258, V003T01A064; 12 pages
Published Online:
August 4, 2014
Citation
Uzol, O, Camcı, C, & Glezer, B. "Aerodynamic Loss Characteristics of a Turbine Blade With Trailing Edge Coolant Ejection: Part 1 — Effect of Cut-Back Length, Spanwise Rib Spacing, Free Stream Reynolds Number and Chordwise Rib Length on Discharge Coefficients." Proceedings of the ASME Turbo Expo 2000: Power for Land, Sea, and Air. Volume 3: Heat Transfer; Electric Power; Industrial and Cogeneration. Munich, Germany. May 8–11, 2000. V003T01A064. ASME. https://doi.org/10.1115/2000-GT-0258
Download citation file:
23
Views
Related Proceedings Papers
Related Articles
Effects of Ribbed Crossflow Channel in a Turbine Blade on Film Cooling Performance of Diffusion Slot Holes with Various Cross Section Orientations
J. Turbomach (January,2025)
Investigation of the Discharge Coefficient for Laidback Fan-Shaped Holes on Turbine Blades Under Internal Crossflow Condition
J. Turbomach (January,2025)
Numerical Study of Aerodynamic Losses of Effusion Cooling Holes in Aero-Engine Combustor Liners
J. Eng. Gas Turbines Power (February,2011)
Related Chapters
Antilock-Braking System Using Fuzzy Logic
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Introduction I: Role of Engineering Science
Fundamentals of heat Engines: Reciprocating and Gas Turbine Internal Combustion Engines
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential