Magnetic resonance imaging (MRI) offers many benefits to image-guided interventions, including excellent soft tissue distinction, little to no repositioning of the patient, and zero radiation exposure. The closed, narrow bore of a high field MRI scanner limits clinician access to the patient, such that an MR-compatible robot is essentially required for many potential interventions. A robotic system of this kind could additionally provide the clinician increased accuracy and more degrees of freedom within the minimally invasive context. Fluid power is an excellent type of actuation to use inside the MRI scanner, as such actuators can be designed free of magnetic and electrical components. However, there are no fluid power actuators readily available that are suitable for use in the operating room. This paper reports a compact, intrinsically safe, sterilizable fluid power actuator. Using additive manufacturing processes, the actuator was printed in a single build. Thus, it is composed of several integrated parts in a compact design. Employing an inchworm-like behavior, the linear actuator can advance or retract a needle or mechanism rod in discrete steps; thus the device is intrinsically safe. The actuator is fluid agnostic, but a pneumatic prototype is presented here with initial testing results. For the pneumatic case, sub-step positioning control has been tested using a nonlinear, model-based controller, and the mean steady-state error was 0.025 mm. Thus this type of actuator appears to be promising solution for use in MRI-guided interventions.
Skip Nav Destination
ASME/BATH 2013 Symposium on Fluid Power and Motion Control
October 6–9, 2013
Sarasota, Florida, USA
Conference Sponsors:
- Fluid Power Systems and Technology Division
ISBN:
978-0-7918-5608-6
PROCEEDINGS PAPER
Design and Precision Control of an MR-Compatible Flexible Fluidic Actuator Available to Purchase
David B. Comber,
David B. Comber
Vanderbilt University, Nashville, TN
Search for other works by this author on:
Jonathon E. Slightam,
Jonathon E. Slightam
Milwaukee School of Engineering, Milwaukee, WI
Search for other works by this author on:
Eric J. Barth,
Eric J. Barth
Vanderbilt University, Nashville, TN
Search for other works by this author on:
Vito R. Gervasi,
Vito R. Gervasi
Milwaukee School of Engineering, Milwaukee, WI
Search for other works by this author on:
Robert J. Webster, III
Robert J. Webster, III
Vanderbilt University, Nashville, TN
Search for other works by this author on:
David B. Comber
Vanderbilt University, Nashville, TN
Jonathon E. Slightam
Milwaukee School of Engineering, Milwaukee, WI
Eric J. Barth
Vanderbilt University, Nashville, TN
Vito R. Gervasi
Milwaukee School of Engineering, Milwaukee, WI
Robert J. Webster, III
Vanderbilt University, Nashville, TN
Paper No:
FPMC2013-4481, V001T01A048; 9 pages
Published Online:
February 26, 2014
Citation
Comber, DB, Slightam, JE, Barth, EJ, Gervasi, VR, & Webster, RJ, III. "Design and Precision Control of an MR-Compatible Flexible Fluidic Actuator." Proceedings of the ASME/BATH 2013 Symposium on Fluid Power and Motion Control. ASME/BATH 2013 Symposium on Fluid Power and Motion Control. Sarasota, Florida, USA. October 6–9, 2013. V001T01A048. ASME. https://doi.org/10.1115/FPMC2013-4481
Download citation file:
64
Views
Related Proceedings Papers
Related Articles
Design of a Novel Flexible Robotic Laparoscope Using a Two Degrees-of-Freedom Cable-Driven Continuum Mechanism With Major Arc Notches
J. Mechanisms Robotics (December,2023)
Sliding Mode Control of Mechanical Systems Actuated by Shape Memory Alloy
J. Dyn. Sys., Meas., Control (January,2009)
MRI–Compatible Fluid-Powered Medical Devices
Mechanical Engineering (June,2013)
Related Chapters
An Adaptive Fuzzy Control for a Multi-Degree-of-Freedom System
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Time-Varying Coefficient Aided MM Scheme
Robot Manipulator Redundancy Resolution
QP Based Encoder Feedback Control
Robot Manipulator Redundancy Resolution