The most common surgical procedure used to treat right ventricular heart failure is the Fontan procedure, which connects the superior vena cava and the inferior vena cava directly to the left and right pulmonary arteries bypassing the right atrium. Many studies have been performed to improve the Fontan procedure. Research has been done on a four-way connector that can both passively and actively improve flow characteristics of the junction between the Superior Vena Cava (SVC), Inferior Vena Cava (IVC), Left Pulmonary Artery (LPA) and Right Pulmonary Artery (RPA), using an optimized connector and dual propeller system. However, the configuration of these devices do not specify propeller motor placement and has a stagnation point in the center of the connector. This study focuses on creating a housing for the motor in the center of the connector to reduce the stagnation area and further stabilize the propellers. To do this, we created a program in ANSYS that utilizes the design-of-experiment (DOE) function to minimize power-loss and stagnation points in the connector for a given geometry. First, a CFD model is created to simulate the blood flow inside the connector with different housing geometries. The shape and size of the housing are used as parameters for the DOE process. In this study, an enhanced central composite design technique is used to discretize the design space. The objective functions in the DOE are red blood cell residence time and power loss. It was confirmed that the addition of the housing did decrease the size of the stagnation point. In fact, the housing added in stabilizing the flow through the connector by creating a more defined flow path. Because the flowrates from the IVC and SVC are not the same, the best configuration for the housing was found to be asymmetric along the axis of the pulmonary artery. While this is a continuation of previous studies, the creation of an optimized housing for the motors for the propellers makes implementation of the propeller idea more viable in a real life situation. The added stability of the propellers provided by the housing can also decrease the risk of propeller failure due to rotordynamic instability.
Skip Nav Destination
ASME 2018 5th Joint US-European Fluids Engineering Division Summer Meeting
July 15–20, 2018
Montreal, Quebec, Canada
Conference Sponsors:
- Fluids Engineering Division
ISBN:
978-0-7918-5155-5
PROCEEDINGS PAPER
Hemodynamics Characteristics of a Four-Way Right-Atrium Bypass Connector With an Optimized Central Diverter
Elizabeth Mack,
Elizabeth Mack
Virginia Tech, Blacksburg, VA
Search for other works by this author on:
Alexandrina Untaroiu
Alexandrina Untaroiu
Virginia Tech, Blacksburg, VA
Search for other works by this author on:
Elizabeth Mack
Virginia Tech, Blacksburg, VA
Jakin Jagani
Virginia Tech, Blacksburg, VA
Alexandrina Untaroiu
Virginia Tech, Blacksburg, VA
Paper No:
FEDSM2018-83167, V001T02A002; 10 pages
Published Online:
October 24, 2018
Citation
Mack, E, Jagani, J, & Untaroiu, A. "Hemodynamics Characteristics of a Four-Way Right-Atrium Bypass Connector With an Optimized Central Diverter." Proceedings of the ASME 2018 5th Joint US-European Fluids Engineering Division Summer Meeting. Volume 1: Flow Manipulation and Active Control; Bio-Inspired Fluid Mechanics; Boundary Layer and High-Speed Flows; Fluids Engineering Education; Transport Phenomena in Energy Conversion and Mixing; Turbulent Flows; Vortex Dynamics; DNS/LES and Hybrid RANS/LES Methods; Fluid Structure Interaction; Fluid Dynamics of Wind Energy; Bubble, Droplet, and Aerosol Dynamics. Montreal, Quebec, Canada. July 15–20, 2018. V001T02A002. ASME. https://doi.org/10.1115/FEDSM2018-83167
Download citation file:
10
Views
0
Citations
Related Proceedings Papers
Related Articles
Hemodynamics Characteristics of a Four-Way Right-Atrium Bypass Connector
J. Fluids Eng (December,2018)
Optimization of Inflow Waveform Phase-Difference for Minimized Total Cavopulmonary Power Loss
J Biomech Eng (March,2010)
Flow Input Waveform Effects on the Temporal and Spatial Wall Shear Stress Gradients in a Femoral Graft-Artery Connector
J Biomech Eng (November,1996)
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Generating Synthetic Electrocardiogram Signals Withcontrolled Temporal and Spectral Characteristics
Intelligent Engineering Systems through Artificial Neural Networks Volume 18
DYNAMIC GEOHAZARD MANAGEMENT IN CHALLENGING ENVIRONMENT
Pipeline Integrity Management Under Geohazard Conditions (PIMG)