Drag reduction (DR) experiments with combined micro-bubble and polymer solution injection were conducted in a water tunnel at the ARL/Penn State. Previous research has shown that gas injected upstream of polymer produced higher levels of DR than expected based on DR levels observed with the independent injection of micro-bubbles or polymer alone. This synergy between the two injection processes was speculated to have resulted from a decrease in the diffusion rate of injected polymer away from the surface by the effects of the micro-bubbles. The slowed polymer diffusion should extend the length of the zone where large polymer DR occurs. In the current work, a confocal-style laser induced fluorescence based probe was developed and used to measure the wall concentration of injected polymer solutions and injected water with and without upstream micro-bubble injection. The local wall concentrations were increased with gas injection by more than an order of magnitude in many cases. These results show that synergistic drag reduction occurs with combined injection as a result of increased polymer wall concentrations.
Skip Nav Destination
ASME 2006 2nd Joint U.S.-European Fluids Engineering Summer Meeting Collocated With the 14th International Conference on Nuclear Engineering
July 17–20, 2006
Miami, Florida, USA
Conference Sponsors:
- Fluids Engineering Division
ISBN:
0-7918-4750-0
PROCEEDINGS PAPER
Synergy Mechanism in Combined Polymer and Microbubble Drag Reduction: Decreased Polymer Diffusion
Howard L. Petrie,
Howard L. Petrie
Pennsylvania State University, State College, PA
Search for other works by this author on:
Arnold A. Fontaine,
Arnold A. Fontaine
Pennsylvania State University, State College, PA
Search for other works by this author on:
Michael J. Moeny,
Michael J. Moeny
Pennsylvania State University, State College, PA
Search for other works by this author on:
Steven Deutsch
Steven Deutsch
Pennsylvania State University, State College, PA
Search for other works by this author on:
Howard L. Petrie
Pennsylvania State University, State College, PA
Arnold A. Fontaine
Pennsylvania State University, State College, PA
Michael J. Moeny
Pennsylvania State University, State College, PA
Steven Deutsch
Pennsylvania State University, State College, PA
Paper No:
FEDSM2006-98569, pp. 1585-1594; 10 pages
Published Online:
September 5, 2008
Citation
Petrie, HL, Fontaine, AA, Moeny, MJ, & Deutsch, S. "Synergy Mechanism in Combined Polymer and Microbubble Drag Reduction: Decreased Polymer Diffusion." Proceedings of the ASME 2006 2nd Joint U.S.-European Fluids Engineering Summer Meeting Collocated With the 14th International Conference on Nuclear Engineering. Volume 1: Symposia, Parts A and B. Miami, Florida, USA. July 17–20, 2006. pp. 1585-1594. ASME. https://doi.org/10.1115/FEDSM2006-98569
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Impact of Polymer Degradation on Past Studies of the Mean Velocity Profile in Turbulent Boundary Layers
J. Fluids Eng (August,2021)
Drag Reduction in Turbulent Flow With Polymer Additives
J. Fluids Eng (May,2009)
Related Chapters
Introduction to Polymers
Introduction to Plastics Engineering
Concepts from Polymer Physics
Introduction to Plastics Engineering
Structure, Properties, and Applications of Plastics
Introduction to Plastics Engineering