At the U.S. Department of Energy’s Hanford Site, 300-hp mixer pumps will be installed in the 4,000-m3 double-shell tanks (DSTs) to stir the radioactive sludge and supernatant liquid waste so that it can be retrieved for subsequent treatment and disposal. A baseline mixer pump that has been used in the DSTs has an intake at the bottom and two injection nozzles at the top. The pump is placed approximately 0.46 m above the bottom of the tank. We compared the predicted mixing performance of this baseline pump with an alternative pump—an inverted pump with the inlet at the top and injection nozzles at the bottom. Model predictions were compared with some measured data. We evaluated 16 cases of baseline and inverted pump conditions with mixer pumps situated at levels ranging from right on the tank bottom to 0.83 m above the tank bottom. Model results generally indicated sludge erosion is greater the closer the pump’s injection nozzle is to the tank bottom. These results provided an evaluation of mixing performance for use in a cost, risk, and benefit analysis to determine which pump configuration should be used for DST waste retrieval activities.
Skip Nav Destination
ASME/JSME 2003 4th Joint Fluids Summer Engineering Conference
July 6–10, 2003
Honolulu, Hawaii, USA
Conference Sponsors:
- Fluids Engineering Division
ISBN:
0-7918-3696-7
PROCEEDINGS PAPER
Optimal Pump Elevation and Configuration for Mixing Erosion-Resisting Radioactive Tank Waste
Yasuo Onishi,
Yasuo Onishi
Pacific Northwest National Laboratory, Richland, WA
Search for other works by this author on:
Donald S. Trent,
Donald S. Trent
Pacific Northwest National Laboratory, Richland, WA
Search for other works by this author on:
Satoru T. Yokuda,
Satoru T. Yokuda
Pacific Northwest National Laboratory, Richland, WA
Search for other works by this author on:
Catherine A. Hier Majumder,
Catherine A. Hier Majumder
University of Minnesota, Minneapolis, MN
Search for other works by this author on:
Edgar W. Martinen,
Edgar W. Martinen
CH2M Hill Hanford Group, Inc., Richland, WA
Search for other works by this author on:
Curt A. Rieck
Curt A. Rieck
Numatec Hanford Corporation, Richland, WA
Search for other works by this author on:
Yasuo Onishi
Pacific Northwest National Laboratory, Richland, WA
Donald S. Trent
Pacific Northwest National Laboratory, Richland, WA
Satoru T. Yokuda
Pacific Northwest National Laboratory, Richland, WA
Catherine A. Hier Majumder
University of Minnesota, Minneapolis, MN
Edgar W. Martinen
CH2M Hill Hanford Group, Inc., Richland, WA
Curt A. Rieck
Numatec Hanford Corporation, Richland, WA
Paper No:
FEDSM2003-45502, pp. 907-913; 7 pages
Published Online:
February 4, 2009
Citation
Onishi, Y, Trent, DS, Yokuda, ST, Hier Majumder, CA, Martinen, EW, & Rieck, CA. "Optimal Pump Elevation and Configuration for Mixing Erosion-Resisting Radioactive Tank Waste." Proceedings of the ASME/JSME 2003 4th Joint Fluids Summer Engineering Conference. Volume 1: Fora, Parts A, B, C, and D. Honolulu, Hawaii, USA. July 6–10, 2003. pp. 907-913. ASME. https://doi.org/10.1115/FEDSM2003-45502
Download citation file:
4
Views
Related Proceedings Papers
Related Articles
Enhancing the Aggressive Intensity of a Cavitating Jet by Means of the Nozzle Outlet Geometry
J. Fluids Eng (October,2011)
Erosive Wear Model of Slurry Pump Impeller
J. Tribol (April,2010)
A Piezoelectric Valve-Less Pump-Dynamic Model
J. Fluids Eng (March,2001)
Related Chapters
Openings
Guidebook for the Design of ASME Section VIII Pressure Vessels
Openings
Guidebook for the Design of ASME Section VIII Pressure Vessels, Third Edition
Section VIII: Division 2—Alternative Rules
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 2, Second Edition: Criteria and Commentary on Select Aspects of the Boiler & Pressure Vessel and Piping Codes