IHI has succeeded in development of a new generation Automated People Mover (APM). One of the features of this APM is the composite car body which enables stylish exterior, spacious cabin and light weight. This feature demanded the development of a new Heating, Ventilating, and Air-Conditioning (HVAC) system, which does not have any devices on the roof of the car, to avoid heavy weight on the composite body and to keep the cabin ceiling high for passenger comfort. Consequently we adopted a new HVAC flow system in which the air is supplied upwards from the bottom of the side windows while all the mechanical devices are placed under the floor. However, when the prototype was first designed, it caused congested flow channel due to its location and we had to have ducts that were too small. It was unexpectedly difficult to keep the space for HVAC system like in an ordinary layout. So at first, the prototype vehicle did not have enough HVAC performance due to lack of air flow. Therefore we performed full review of the duct system. We made desk analysis, duct model test, experiment on the prototype, and CFD simulation, for the improvement of the new HVAC flow system. Finally, we have established an excellent system with the new layout which has been validated on the prototype vehicle. In this paper, we describe the process of developing a new HVAC system, based on the results of actual measurement as well as CFD simulation.
Skip Nav Destination
ASME-JSME-KSME 2011 Joint Fluids Engineering Conference
July 24–29, 2011
Hamamatsu, Japan
Conference Sponsors:
- Fluids Engineering Division
ISBN:
978-0-7918-4440-3
PROCEEDINGS PAPER
Development of a New HVAC Flow System for the Next Generation Automated People Mover
Miho Nagaoka,
Miho Nagaoka
IHI Corporation, Yokohama, Japan
Search for other works by this author on:
Masafumi Kawai,
Masafumi Kawai
IHI Corporation, Yokohama, Japan
Search for other works by this author on:
Norihiro Takai
Norihiro Takai
IHI Corporation, Tokyo, Japan
Search for other works by this author on:
Miho Nagaoka
IHI Corporation, Yokohama, Japan
Masafumi Kawai
IHI Corporation, Yokohama, Japan
Norihiro Takai
IHI Corporation, Tokyo, Japan
Paper No:
AJK2011-23023, pp. 957-964; 8 pages
Published Online:
May 25, 2012
Citation
Nagaoka, M, Kawai, M, & Takai, N. "Development of a New HVAC Flow System for the Next Generation Automated People Mover." Proceedings of the ASME-JSME-KSME 2011 Joint Fluids Engineering Conference. ASME-JSME-KSME 2011 Joint Fluids Engineering Conference: Volume 1, Symposia – Parts A, B, C, and D. Hamamatsu, Japan. July 24–29, 2011. pp. 957-964. ASME. https://doi.org/10.1115/AJK2011-23023
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
Mitigation Options to Reduce Peak Air Temperature and Air-Conditioning Demand in the Context of a Warming Climate for a Tropical Coastal City
J. Eng. Sustain. Bldgs. Cities (May,2021)
Dynamic Design Procedure for HVAC Ducts
J. Pressure Vessel Technol (November,1988)
Numerical Model of the Temperature Control Curve Linearity of HVAC Module in Automobile Air-Conditioning System and Applications
J. Thermal Sci. Eng. Appl (December,2010)
Related Chapters
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems
The Cause of Most Field Problems
Heat Exchanger Engineering Techniques
Inside the Building
Geothermal Heat Pump and Heat Engine Systems: Theory and Practice