The two 450t/h CFB units of the Zeran heat and power plant in Warsaw, Poland, are nearly identical in design, except for the cyclones. While the first CFB unit Zeran A which was commissioned in 1995 had cyclones of a prior design, the second unit Zeran B, which went into operation in late 2001, was equipped with high efficiency cyclones with the latest technological developments. The impact of the cyclone design is clearly visible in the operational data. Due to the high cyclone efficiency, the internal circulation became much higher and the fineness of the circulating particles was shifted to finer particles. As a result, the heat transfer in the furnace was boosted and the temperature profile became more even. This had a significant positive effect on the emissions, especially NOx and on the limestone consumption, which was considerably reduced.
Skip Nav Destination
17th International Conference on Fluidized Bed Combustion
May 18–21, 2003
Jacksonville, Florida, USA
Conference Sponsors:
- Advanced Energy Systems
ISBN:
0-7918-3680-0
PROCEEDINGS PAPER
Operational Experience With High Efficiency Cyclones: Comparison Between Boiler A and B in the Zeran Power Plant — Warsaw, Poland
Ireneusz Lalak,
Ireneusz Lalak
Elektrocieptownie Warszawskie, Warsaw, Poland
Search for other works by this author on:
Joachim Seeber,
Joachim Seeber
ALSTOM Power Boiler GmbH, Stuttgart, Germany
Search for other works by this author on:
Frank Kluger,
Frank Kluger
ALSTOM Power Boiler GmbH, Stuttgart, Germany
Search for other works by this author on:
Stanislaw Krupka
Stanislaw Krupka
RAFAKO S.A., Raciborz, Poland
Search for other works by this author on:
Ireneusz Lalak
Elektrocieptownie Warszawskie, Warsaw, Poland
Joachim Seeber
ALSTOM Power Boiler GmbH, Stuttgart, Germany
Frank Kluger
ALSTOM Power Boiler GmbH, Stuttgart, Germany
Stanislaw Krupka
RAFAKO S.A., Raciborz, Poland
Paper No:
FBC2003-146, pp. 685-690; 6 pages
Published Online:
December 22, 2008
Citation
Lalak, I, Seeber, J, Kluger, F, & Krupka, S. "Operational Experience With High Efficiency Cyclones: Comparison Between Boiler A and B in the Zeran Power Plant — Warsaw, Poland." Proceedings of the 17th International Conference on Fluidized Bed Combustion. 17th International Conference on Fluidized Bed Combustion. Jacksonville, Florida, USA. May 18–21, 2003. pp. 685-690. ASME. https://doi.org/10.1115/FBC2003-146
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
An Improved Cluster-Renewal Model for the Estimation of Heat Transfer Coefficients on the Furnace Walls of Commercial Circulating Fluidized Bed Boilers
J. Heat Transfer (December,2004)
Experiment and Numerical Simulation Study of Low-Nitrogen Combustion Technology Inside Small Gas Boiler
J. Energy Resour. Technol (October,2023)
Design and Performance Verification of a 62-MWt CFB Boiler
J. Eng. Gas Turbines Power (January,2001)
Related Chapters
Basic Concepts
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies