In the present study, a numerical simulation is carried out in order to optimize the length of the mixing part of a T-junction to obtain a homogenous temperature distribution at the outlet. Different RANS turbulence models are tested: the Realizable k-ε the k-ω standard and the k-ω SST. The behavior of turbulent mixing flow in the mixing part of the pipe has helped in understanding the causes of discrepancy between the models used. The test case analysed in this paper is an unsteady state three-dimensional turbulent flow. The numerical results obtained show that there is a difference in the prediction of the thermal field when different models are used. The results obtained for both k-ω standard and SST models are closer compared with those given by the Realizable k-ε model. The numerical results show that a distance of x/L = 0.625 from the branch is enough to supply devices with a constant temperature.

This content is only available via PDF.