This study is to establish a preliminary computer assisted simulation model for cryoablation of a prostate cancer. It is hoped that the results from this study can supply valuable data for the clinician to refer to before a real cryosurgery or cryotherapy. In order to reach the goal of real implementation, a radiologist and an urologist in a medical center in addition to the engineering specialist from the university participated in this interdisciplinary research program. Firstly, hundreds of the two-dimensional medical imaging photos for the patient are obtained from the magnetic resonance imaging (MRI) in the imaging department of hospital. Through the imaging reconstructive software, these photos are trimmed into building a three-dimensional solid modeling. In this step, the urethra, bladder, prostate and rectum are segmented separately into an engineering graphic solid model with high resolution. Secondly, the number of probes, the position of each probe, and the operating time duration of each probe are determined in advance according to the clinical experience from a surgeon. Meanwhile, these data are transferred into the software package of thermal calculation for numerical simulations. Thirdly, the energy equation in the commercial software is modified to behave bio-heat transfer model by the input of user subroutines. Moreover, the occurrence of phase change during some specified temperature range and the latent heat of fusion are also incorporated into bio-heat transfer model to simulate the clinical situation for cryoablation of prostate cancer. In the simulation model, the three-dimensional transient temperature distributions based on cryosurgery for prostate cancer have been demonstrated precisely. The cryoprobes with various freezing time are considered to observe the temperature distribution. In addition, the frozen rectum is displayed in a region enclosed by a critical isotherm of 0°C. The simulated results for cryosurgery of prostate cancer can be supplied for practicing physicians as reference to greatly improve the effectiveness of cryosurgery.
Skip Nav Destination
ASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis
July 12–14, 2010
Istanbul, Turkey
Conference Sponsors:
- International
ISBN:
978-0-7918-4915-6
PROCEEDINGS PAPER
Computer Assisted Simulation Model for Cryoablation of Prostate Cancer Including the Possible Injury of Rectum
Chih-Wei Chen,
Chih-Wei Chen
Tatung University, Taipei, Taiwan
Search for other works by this author on:
Hong-Sen Kou,
Hong-Sen Kou
Tatung University, Taipei, Taiwan
Search for other works by this author on:
Hsueh-Erh Liu,
Hsueh-Erh Liu
Chang Gung University, Tao-Yuan, Taiwan
Search for other works by this author on:
Cheng-Keng Chuang,
Cheng-Keng Chuang
Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
Search for other works by this author on:
Li-Jen Wang
Li-Jen Wang
Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
Search for other works by this author on:
Chih-Wei Chen
Tatung University, Taipei, Taiwan
Hong-Sen Kou
Tatung University, Taipei, Taiwan
Hsueh-Erh Liu
Chang Gung University, Tao-Yuan, Taiwan
Cheng-Keng Chuang
Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
Li-Jen Wang
Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
Paper No:
ESDA2010-25449, pp. 843-850; 8 pages
Published Online:
December 28, 2010
Citation
Chen, C, Kou, H, Liu, H, Chuang, C, & Wang, L. "Computer Assisted Simulation Model for Cryoablation of Prostate Cancer Including the Possible Injury of Rectum." Proceedings of the ASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis. ASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis, Volume 1. Istanbul, Turkey. July 12–14, 2010. pp. 843-850. ASME. https://doi.org/10.1115/ESDA2010-25449
Download citation file:
2
Views
0
Citations
Related Proceedings Papers
Related Articles
Smooth Anatomical Models From 3D Imaging
J. Med. Devices (June,2009)
Numerical Simulation for Heat Transfer in Prostate Cancer Cryosurgery
J Biomech Eng (April,2005)
Infrascanner: Cost Effective, Mobile Medical Imaging System for Detecting Hemotomas
J. Med. Devices (June,2011)
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Using Statistical Learning Theory to Improve Treatment Response for Metastatic Colorectal Carcinoma
Intelligent Engineering Systems through Artificial Neural Networks, Volume 20
Genetic Approach for Predicting the Missing Value of the Pixel
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3