The supplementary firing is one of the techniques which are used to increase the output power of the combined cycle power plants (CCPP). The low construction cost per generated power encourages designers to consider it in the new CCPP. In this paper the thermal and exergy analyses of HRSG for various operating conditions in variation of loads and variation of ambient temperature carried out. They are based on the performance test data at different operating conditions. The objective of these analyses is to present the effects of supplementary firing on gross power output, combined cycle efficiency and the exergy loss in Heat Recovery Steam Generator (HRSG) devices at different ambient temperatures and different gas turbine loads. This study is based on 420 MW Neka combined cycle power plant operation and performance data sheet. The results show that the most effective components for the exergy losses are stack, HP Evaporator and HP Superheater at the rated load. The results reveal that although the supplementary firing increases the gross output power of the combined cycle power plant, however it increases the total exergy loss of HRSG and consequently decreases the total exergy efficiency. Moreover, it shows that the most effective components for the exergy losses in this case are HP Evaporator and HP Economizer at partial loads. Also, LP Evaporator and LP Superheater have the same effect at the different ambient temperature.
Skip Nav Destination
ASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis
July 12–14, 2010
Istanbul, Turkey
Conference Sponsors:
- International
ISBN:
978-0-7918-4915-6
PROCEEDINGS PAPER
Second Law Based Analysis of Supplementary Firing Effects on the Heat Recovery Steam Generator in a Combined Cycle Power Plant
H. Karrabi,
H. Karrabi
Sharif University of Technology, Tehran, Iran
Search for other works by this author on:
S. Rasoulipour
S. Rasoulipour
Sharif University of Technology, Tehran, Iran
Search for other works by this author on:
H. Karrabi
Sharif University of Technology, Tehran, Iran
S. Rasoulipour
Sharif University of Technology, Tehran, Iran
Paper No:
ESDA2010-24660, pp. 201-209; 9 pages
Published Online:
December 28, 2010
Citation
Karrabi, H, & Rasoulipour, S. "Second Law Based Analysis of Supplementary Firing Effects on the Heat Recovery Steam Generator in a Combined Cycle Power Plant." Proceedings of the ASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis. ASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis, Volume 1. Istanbul, Turkey. July 12–14, 2010. pp. 201-209. ASME. https://doi.org/10.1115/ESDA2010-24660
Download citation file:
11
Views
Related Proceedings Papers
Related Articles
Second Law Efficiency of the Rankine Bottoming Cycle of a Combined Cycle Power Plant
J. Eng. Gas Turbines Power (January,2010)
A New Thermoeconomic Method for the Location of Causes of Malfunctions in Energy Systems
J. Energy Resour. Technol (March,2007)
Energy, Exergy, Environmental (3E) and Parametric Assessment of a Triple-Pressure Reheat Combined-Cycle Power Plant
J. Energy Resour. Technol (November,2021)
Related Chapters
Performance Testing of Combined Cycle Power Plant
Handbook for Cogeneration and Combined Cycle Power Plants, Second Edition
Scope
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration