The aim of this work is to study the influence of pressure loss parameters from a district heating system on the distribution of fluid flow rates. The research was finalized by improving the mathematical model of a district heating network, which comprises an algebraic non-linear system that synthesizes flow balance equations of a stationary flow. This enhanced model indicates the influence of every consumer’s heat demand supplied from a district heating network on the fluid flow rates distribution based on the means of the implicit function theorem. The originality of the method consists of considering the network a sensitive system that responds to the variations of input parameters (pressure loss parameters) by variations of output parameter (fluid flow rates). The main advantage is that the engineer in charge with exploitation of the heating system may understand what happens with the flow allocations when pressure loss parameters of the network are different from the nominal ones, without making any measurements on the field or computations using new scenarios. The method presented in this paper facilitates the choice of the best decision concerning balancing and practical management of radial heating networks.
Skip Nav Destination
ASME 2008 9th Biennial Conference on Engineering Systems Design and Analysis
July 7–9, 2008
Haifa, Israel
Conference Sponsors:
- International
ISBN:
978-0-7918-4838-8
PROCEEDINGS PAPER
Hydraulic Analysis of a District Heating Network
Daniela Popescu,
Daniela Popescu
Technical University Gheorghe Asachi Iasi, Iasi, Romania
Search for other works by this author on:
Elena Serban,
Elena Serban
Technical University Gheorghe Asachi Iasi, Iasi, Romania
Search for other works by this author on:
Carmen-Ema Panaite,
Carmen-Ema Panaite
Technical University Gheorghe Asachi Iasi, Iasi, Romania
Search for other works by this author on:
Abel Herna´ndez-Guerrero
Abel Herna´ndez-Guerrero
Universidad de Guanajuato, Salamanca, Guanajuato, Me´xico
Search for other works by this author on:
Daniela Popescu
Technical University Gheorghe Asachi Iasi, Iasi, Romania
Elena Serban
Technical University Gheorghe Asachi Iasi, Iasi, Romania
Carmen-Ema Panaite
Technical University Gheorghe Asachi Iasi, Iasi, Romania
Abel Herna´ndez-Guerrero
Universidad de Guanajuato, Salamanca, Guanajuato, Me´xico
Paper No:
ESDA2008-59352, pp. 133-137; 5 pages
Published Online:
July 6, 2009
Citation
Popescu, D, Serban, E, Panaite, C, & Herna´ndez-Guerrero, A. "Hydraulic Analysis of a District Heating Network." Proceedings of the ASME 2008 9th Biennial Conference on Engineering Systems Design and Analysis. Volume 4: Fatigue and Fracture; Fluids Engineering; Heat Transfer; Mechatronics; Micro and Nano Technology; Optical Engineering; Robotics; Systems Engineering; Industrial Applications. Haifa, Israel. July 7–9, 2008. pp. 133-137. ASME. https://doi.org/10.1115/ESDA2008-59352
Download citation file:
14
Views
Related Proceedings Papers
Related Articles
Combined Heat and Power Plant and District Heating and Cooling Network: A Test-Case in Italy With Integration of Renewable Energy
J. Sol. Energy Eng (October,2018)
Closed-Loop Analysis in Semantic Tolerance Modeling
J. Mech. Des (June,2008)
Properties of Hydrocarbon Mixtures at High Pressures
Trans. ASME (January,1932)
Related Chapters
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Completing the Picture
Air Engines: The History, Science, and Reality of the Perfect Engine
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential