In this paper, a building energy simulation code, EnergyPlus, was used to study selected important conditions, i.e. wall boundary conditions and locations, which potentially affect the energy consumption and thermal management of a popular data center model. The data center model having 1120 servers distributed in four rows of rack was investigated under two major climate conditions — hot and humid (Miami, FL), and cool and humid (Chicago, IL), and under five different wall boundary conditions. The data center model was first simulated under a well-mixed single-zone condition as a baseline. Then, a multi-zone approach was proposed to resolve the hot and cold aisles and used to investigate the data center performance. Both monthly and annual overall energy consumption as well as cooling load reports were analyzed and compared among various boundary conditions. In addition, monthly thermal behavior of hot and cold aisle zones within the data center was analyzed. The simulation results show that thermal performance of the data center is significantly affected by locations or climate conditions. The effects of location and wall boundary conditions are particularly appreciable during the summer and winter seasons.
Skip Nav Destination
ASME 2013 7th International Conference on Energy Sustainability collocated with the ASME 2013 Heat Transfer Summer Conference and the ASME 2013 11th International Conference on Fuel Cell Science, Engineering and Technology
July 14–19, 2013
Minneapolis, Minnesota, USA
Conference Sponsors:
- Advanced Energy Systems Division
- Solar Energy Division
ISBN:
978-0-7918-5551-5
PROCEEDINGS PAPER
A Multi-Zone Building Energy Simulation of a Data Center Model With Hot and Cold Aisles
Long Phan,
Long Phan
Florida International University, Miami, FL
Search for other works by this author on:
Cheng-Xian Lin,
Cheng-Xian Lin
Florida International University, Miami, FL
Search for other works by this author on:
Mirko Schäfer
Mirko Schäfer
University of Kassel, Kassel, Hesse, Germany
Search for other works by this author on:
Long Phan
Florida International University, Miami, FL
Cheng-Xian Lin
Florida International University, Miami, FL
Mirko Schäfer
University of Kassel, Kassel, Hesse, Germany
Paper No:
ES2013-18089, V001T01A006; 17 pages
Published Online:
December 22, 2013
Citation
Phan, L, Lin, C, & Schäfer, M. "A Multi-Zone Building Energy Simulation of a Data Center Model With Hot and Cold Aisles." Proceedings of the ASME 2013 7th International Conference on Energy Sustainability collocated with the ASME 2013 Heat Transfer Summer Conference and the ASME 2013 11th International Conference on Fuel Cell Science, Engineering and Technology. ASME 2013 7th International Conference on Energy Sustainability. Minneapolis, Minnesota, USA. July 14–19, 2013. V001T01A006. ASME. https://doi.org/10.1115/ES2013-18089
Download citation file:
13
Views
Related Proceedings Papers
Related Articles
Viability of Dynamic Cooling Control in a Data Center
Environment
J. Electron. Packag (June,2006)
Introducing a Novel Air Handling Unit Based on Focusing on Turbulent Exhaust Air Energy-Exergy Recovery Potential
J. Energy Resour. Technol (November,2020)
Performance of Thermoactive Foundations for Commercial Buildings
J. Sol. Energy Eng (November,2013)
Related Chapters
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems
An Energy Efficient Clustering Method for Wireless Sensor Networks
International Conference on Computer Engineering and Technology, 3rd (ICCET 2011)
The Localized Collocation Meshless Method (LCMM) Framework
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow