An optimization model was created to optimize the input power capacity and storage capacity relative to the output power capacity of a compressed air energy storage (CAES) facility in the Electric Reliability Council of Texas (ERCOT) grid. Historical electricity and non-spinning reserve prices were used to calculate the economic feasibility of CAES in each of the zones in ERCOT. The analysis found that with perfect knowledge of future prices a CAES facility would be economically attractive over the period of years considered, and the non-spinning reserve ancillary service market provided a substantial contribution to the overall revenue of the facility. Optimal input power capacity for the entire period of 2002 through 2010 was found to be about one-quarter of the output capacity in the Houston, South, and North zones in ERCOT and one-half the output power capacity in the West zone in ERCOT. Optimal storage capacity was found to be about 17 hours in the Houston, South, and North zones and 31 hours in the West zone. Optimal values for individual years varied significantly, as did revenues. The negative electricity prices that have occurred historically in the West zone are the consequence of wind generators and lack of transmission capacity to export electricity; this effect gives CAES greater opportunity to perform price arbitrage and improves the economics of such a facility.
Skip Nav Destination
ASME 2011 5th International Conference on Energy Sustainability
August 7–10, 2011
Washington, DC, USA
Conference Sponsors:
- Advanced Energy Systems Division and Solar Energy Division
ISBN:
978-0-7918-5468-6
PROCEEDINGS PAPER
Optimization of Technical and Operational Characteristics of a CAES Facility in West Texas to Balance Intermittent Wind Power
Aaron K. Townsend,
Aaron K. Townsend
The University of Texas at Austin, Austin, TX
Search for other works by this author on:
Michael E. Webber
Michael E. Webber
The University of Texas at Austin, Austin, TX
Search for other works by this author on:
Aaron K. Townsend
The University of Texas at Austin, Austin, TX
Michael E. Webber
The University of Texas at Austin, Austin, TX
Paper No:
ES2011-54366, pp. 2091-2100; 10 pages
Published Online:
March 13, 2012
Citation
Townsend, AK, & Webber, ME. "Optimization of Technical and Operational Characteristics of a CAES Facility in West Texas to Balance Intermittent Wind Power." Proceedings of the ASME 2011 5th International Conference on Energy Sustainability. ASME 2011 5th International Conference on Energy Sustainability, Parts A, B, and C. Washington, DC, USA. August 7–10, 2011. pp. 2091-2100. ASME. https://doi.org/10.1115/ES2011-54366
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
Optimal Design and Control of Wind-Diesel Hybrid Energy Systems for Remote Arctic Mines
J. Energy Resour. Technol (November,2016)
Theoretical Performance Limits of an Isobaric Hybrid Compressed Air Energy Storage System
J. Energy Resour. Technol (October,2018)
Advancements and Challenges in Integrating Renewable Energy Sources Into Distribution Grid Systems: A Comprehensive Review
J. Energy Resour. Technol (September,2024)
Related Chapters
A Utility Perspective of Wind Energy
Wind Turbine Technology: Fundamental Concepts in Wind Turbine Engineering, Second Edition
An Efficient Approach to Power Coefficient and Tip Speed Ratio Relationship Modeling in Maximum Power Point Tracking of Wind Power Generation
International Conference on Software Technology and Engineering (ICSTE 2012)
Role of Wind Energy Technology in India and Neighboring Countries
Wind Energy Applications