The distributed absorption cooling based district heating system was investigated in order to utilizing the reject heat from the combined heat and power (CHP) plant in summer. Compared with the electric compressor cooling, the energy efficient and cost-effectiveness of the distributed absorption cooling were furthermore analyzed by the Fuel Energy Saving Ratio (FESR) method. The sensitivity of some variables, such as the average electric efficiency, heating and electric generation efficiency of the CHP system, and the coefficient of performance (COP) of the chiller, were analyzed. The marginal heating price of the distributed absorption cooling can be obtained. According to the evaluation results, the applicability of the distributed cooling with district heating system is limited by the lower energy efficiency and economical benefits. The approaches to increase the energy efficiency were suggested in this paper. The improved distributed absorption cooling combined with liquid desiccant dehumidification which has higher heating utilization efficiency was put forward and analyzed, and the energy efficiency evaluation results showed that the improved distributed cooling has higher energy efficiency and economical benefits, and great applicability.
Skip Nav Destination
ASME 2009 3rd International Conference on Energy Sustainability collocated with the Heat Transfer and InterPACK09 Conferences
July 19–23, 2009
San Francisco, California, USA
Conference Sponsors:
- Advanced Energy Systems Division and Solar Energy Division
ISBN:
978-0-7918-4890-6
PROCEEDINGS PAPER
The Energy Efficiency and Economic Feasibility Analysis of the Distributed Absorption Cooling Combined With District Heating System
Qunli Zhang,
Qunli Zhang
Tsinghua University, Beijing, China
Search for other works by this author on:
Lihua Li,
Lihua Li
Tsinghua Urban Planning and Designing Institute, Beijing, China
Search for other works by this author on:
Hongfa Di
Hongfa Di
Tsinghua University, Beijing, China
Search for other works by this author on:
Qunli Zhang
Tsinghua University, Beijing, China
Lin Fu
Tsinghua University, Beijing, China
Lihua Li
Tsinghua Urban Planning and Designing Institute, Beijing, China
Hongfa Di
Tsinghua University, Beijing, China
Paper No:
ES2009-90070, pp. 49-55; 7 pages
Published Online:
September 29, 2010
Citation
Zhang, Q, Fu, L, Li, L, & Di, H. "The Energy Efficiency and Economic Feasibility Analysis of the Distributed Absorption Cooling Combined With District Heating System." Proceedings of the ASME 2009 3rd International Conference on Energy Sustainability collocated with the Heat Transfer and InterPACK09 Conferences. ASME 2009 3rd International Conference on Energy Sustainability, Volume 2. San Francisco, California, USA. July 19–23, 2009. pp. 49-55. ASME. https://doi.org/10.1115/ES2009-90070
Download citation file:
16
Views
Related Proceedings Papers
Related Articles
Combined Heat and Power Plant and District Heating and Cooling Network: A Test-Case in Italy With Integration of Renewable Energy
J. Sol. Energy Eng (October,2018)
Incorporating a District Heating/Cooling System Into an Existing Geothermal Power Plant
J. Energy Resour. Technol (June,1998)
Steam Turbines for Cogeneration Power Plants
J. Eng. Power (April,1980)
Related Chapters
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Multiscale Methods for Lightweight Structure and Material Characterization
Advanced Multifunctional Lightweight Aerostructures: Design, Development, and Implementation