Nowadays the capillary plane HVAC terminal system as an advanced terminal air conditioning system is being widely used. It has many advantages such as thermal comfort, energy conservation and saving indoor space etc. In this paper, with the example of a typical residential room where the capillary plane HVAC terminal system is installed, the indoor thermal environment is simulated and the influence of different capillary mat placement modes is analyzed, three operating modes in summer and winter are simulated by using the method of CFD, and the corresponding temperature fields are presented. Based on the simulation results, the temperature fields are appraised from the view of thermal comfort. These will be good references to the design and application of the capillary plane HVAC terminal system.
Skip Nav Destination
ASME 2007 Energy Sustainability Conference
July 27–30, 2007
Long Beach, California, USA
Conference Sponsors:
- Solar Energy Division and Advanced Energy Systems Division
ISBN:
0-7918-4797-7
PROCEEDINGS PAPER
Numerical Simulation of Air Distribution in a Residential Building With Capillary Plane HVAC Terminal System
Wei Bing,
Wei Bing
North China Electric Power University, Baoding, Hebei, P. R. China
Search for other works by this author on:
Jiang Lu,
Jiang Lu
North China Electric Power University, Baoding, Hebei, P. R. China
Search for other works by this author on:
Li Li,
Li Li
North China Electric Power University, Baoding, Hebei, P. R. China
Search for other works by this author on:
Zhiwei Wang
Zhiwei Wang
North China Electric Power University, Baoding, Hebei, P. R. China
Search for other works by this author on:
Wei Bing
North China Electric Power University, Baoding, Hebei, P. R. China
Jiang Lu
North China Electric Power University, Baoding, Hebei, P. R. China
Li Li
North China Electric Power University, Baoding, Hebei, P. R. China
Zhiwei Wang
North China Electric Power University, Baoding, Hebei, P. R. China
Paper No:
ES2007-36149, pp. 745-750; 6 pages
Published Online:
February 24, 2009
Citation
Bing, W, Lu, J, Li, L, & Wang, Z. "Numerical Simulation of Air Distribution in a Residential Building With Capillary Plane HVAC Terminal System." Proceedings of the ASME 2007 Energy Sustainability Conference. ASME 2007 Energy Sustainability Conference. Long Beach, California, USA. July 27–30, 2007. pp. 745-750. ASME. https://doi.org/10.1115/ES2007-36149
Download citation file:
4
Views
Related Proceedings Papers
Related Articles
Evaluation of Thermo-Active Foundations for Heating and Cooling Residential Buildings
J. Sol. Energy Eng (December,2016)
Numerical Model of the Temperature Control Curve Linearity of HVAC Module in Automobile Air-Conditioning System and Applications
J. Thermal Sci. Eng. Appl (December,2010)
What are the Required Conditions for Heavy Structure Buildings to be Thermally Effective in a Hot Humid Climate?
J. Sol. Energy Eng (August,2004)
Related Chapters
Numerical Simulation Research on a Fixed Bed Gasifier
International Conference on Information Technology and Management Engineering (ITME 2011)
Erosive Aggressiveness of Collapsing Cavitating Structures
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
From Tujia Minority People's Residential Buildings to the Application of City Design
International Conference on Optimization Design (ICOD 2010)