This paper presents the transient analysis of fluid flow and heat transfer in a zero boil-off (ZBO) cryogenic storage tank of liquid hydrogen. The system includes a tank with cylindrical wall and oblate spheroidal top and bottom, a heat pipe located along the symmetric axis of the tank, and an active circulator. The heat pipe has a rounded evaporator section at its end. The active circulator is an assembly of a pump body, a suction tube for collecting fluid inside the tank, and a spray nozzle from which the fluid is discharged onto the evaporator section of the heat pipe, which is kept at a constant low temperature, where the heat is removed passively to the condenser section of the heat pipe located outside the tank and eventually to the ambient via a cryocooler. Whenever the maximum temperature inside the tank reaches the boiling point under the working pressure in the tank, the pump is activated to create a forced flow from the nozzle to cool off the heated fluid. After a preset period of time, the pump is shut down and standby until the maximum temperature reaches its threshold again and then the pump starts a new cycle. The transient simulations allow the visualization of flow field and temperature distribution, as well as the computation of maximum and mean temperatures of the fluid at various stages of the pump cycle.
Skip Nav Destination
ASME 2007 Energy Sustainability Conference
July 27–30, 2007
Long Beach, California, USA
Conference Sponsors:
- Solar Energy Division and Advanced Energy Systems Division
ISBN:
0-7918-4797-7
PROCEEDINGS PAPER
Transient Thermal Analysis of Cryogenic Liquid Hydrogen Tank With Active Circulation
Son H. Ho,
Son H. Ho
University of South Florida, Tampa, FL
Search for other works by this author on:
Muhammad M. Rahman
Muhammad M. Rahman
University of South Florida, Tampa, FL
Search for other works by this author on:
Son H. Ho
University of South Florida, Tampa, FL
Muhammad M. Rahman
University of South Florida, Tampa, FL
Paper No:
ES2007-36195, pp. 39-46; 8 pages
Published Online:
February 24, 2009
Citation
Ho, SH, & Rahman, MM. "Transient Thermal Analysis of Cryogenic Liquid Hydrogen Tank With Active Circulation." Proceedings of the ASME 2007 Energy Sustainability Conference. ASME 2007 Energy Sustainability Conference. Long Beach, California, USA. July 27–30, 2007. pp. 39-46. ASME. https://doi.org/10.1115/ES2007-36195
Download citation file:
11
Views
0
Citations
Related Proceedings Papers
Related Articles
Heat Transfer Performance of a Glass Thermosyphon Using Graphene–Acetone Nanofluid
J. Heat Transfer (November,2015)
A Detailed Transient Model of an OTEC Evaporator
J. Eng. Power (July,1981)
Analytical and Experimental Analysis of a High Temperature Mercury Thermosyphon
J. Heat Transfer (September,2009)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Antilock-Braking System Using Fuzzy Logic
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration