Calculation of the therapeutic activity of radioiodine 131I for individualized dosimetry in the treatment of Graves’ disease requires an accurate estimate of the thyroid absorbed radiation dose based on a tracer activity administration of 131I. Common approaches (Marinelli-Quimby formula, MIRD algorithm) use, respectively, the effective half-life of radioiodine in the thyroid and the cumulative activity. Many physicians perform one, two, or at most three tracer dose activity measurements at various times and calculate the required therapeutic activity by ad hoc methods. In this paper, we study the accuracy of estimates of four “target variables”: cumulated activity, effective half-life, maximum activity, and time of maximum activity in the gland. Clinical data from 41 patients who underwent 131I therapy for Graves’ disease at the University Hospital in Pisa, Italy, are used for analysis. The radioiodine kinetics are described using a nonlinear mixed-effects model that includes a measurement error term, and the distributions of the target variables in the patient population are characterized. Using minimum root mean squared error (RMSE) as the criterion, optimal 1-, 2-, and 3-point sampling schedules are determined for estimation of the target variables, and probabilistic bounds are given for the errors under the optimal designs. An optimization algorithm is developed for computing target variables for arbitrary 1-, 2-, and 3-point activity measurements. Taking into consideration 131I effective half-life in the thyroid and measurement noise, the optimal 1-point design for cumulated activity is a measurement one week following the tracer dose. Additional measurements give only a slight improvement in accuracy.
Skip Nav Destination
ASME 2010 Dynamic Systems and Control Conference
September 12–15, 2010
Cambridge, Massachusetts, USA
Conference Sponsors:
- Dynamic Systems and Control Division
ISBN:
978-0-7918-4417-5
PROCEEDINGS PAPER
Accuracy and Optimal Timing of Activity Measurements in Estimating Absorbed Dose of Radioiodine in the Treatment of Graves’ Disease
S. Merrill,
S. Merrill
University of Massachusetts, Amherst, MA
Search for other works by this author on:
S. R. Chipkin,
S. R. Chipkin
University of Massachusetts, Amherst, MA
Search for other works by this author on:
J. Horowitz,
J. Horowitz
University of Massachusetts, Amherst, MA
Search for other works by this author on:
C. V. Hollot,
C. V. Hollot
University of Massachusetts, Amherst, MA
Search for other works by this author on:
A. C. Traino,
A. C. Traino
Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy
Search for other works by this author on:
Y. Chait
Y. Chait
University of Massachusetts, Amherst, MA
Search for other works by this author on:
S. Merrill
University of Massachusetts, Amherst, MA
S. R. Chipkin
University of Massachusetts, Amherst, MA
J. Horowitz
University of Massachusetts, Amherst, MA
C. V. Hollot
University of Massachusetts, Amherst, MA
A. C. Traino
Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy
Y. Chait
University of Massachusetts, Amherst, MA
Paper No:
DSCC2010-4276, pp. 305-312; 8 pages
Published Online:
January 25, 2011
Citation
Merrill, S, Chipkin, SR, Horowitz, J, Hollot, CV, Traino, AC, & Chait, Y. "Accuracy and Optimal Timing of Activity Measurements in Estimating Absorbed Dose of Radioiodine in the Treatment of Graves’ Disease." Proceedings of the ASME 2010 Dynamic Systems and Control Conference. ASME 2010 Dynamic Systems and Control Conference, Volume 1. Cambridge, Massachusetts, USA. September 12–15, 2010. pp. 305-312. ASME. https://doi.org/10.1115/DSCC2010-4276
Download citation file:
8
Views
Related Articles
Multimodal Automated Quantitative Sensory Testing System for Pain Research
J. Med. Devices (June,2011)
Chronic VNS for the Treatment of Morbid Obesity
J. Med. Devices (June,2008)
Design of Pressurized Metered Dose Inhalers Modeling of Internal Flow and Atomization
J. Med. Devices (June,2010)
Related Chapters
Experimental Studies
Nanoparticles and Brain Tumor Treatment
Validation of Elekta iViewGT A-Si EPID Model for Pre-Treatment Dose Verification of IMRT Fields
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)
The Design of a New Bluetooth Adapter
International Conference on Advanced Computer Theory and Engineering, 5th (ICACTE 2012)