A method for the design and development of a feedback device for the treatment of focal dystonic symptoms of Parkinson’s patients is described in this work. This device utilizes haptic feedback produced via a soft pneumatic actuator incorporating zero-volume chambers and channels, to signal to the patient that they are falling into a dystonic pattern so that they themselves can manually break out of the pattern preserving and prolonging the use of the afflicted limb, in this case the hand. The system of detection for the dystonic symptoms is a conductive rubber stretch sensor that detects changes to the circumference of the forearm as the muscles begin to involuntarily contract. The signal from the sensor then feeds into a microcontroller that will activate the onboard pump that will in-turn pulse the soft pneumatic actuator producing a gentle but noticeable haptic sensation on the patient’s arm.
Skip Nav Destination
2019 Design of Medical Devices Conference
April 15–18, 2019
Minneapolis, Minnesota, USA
ISBN:
978-0-7918-4103-7
PROCEEDINGS PAPER
Haptic Neurofeedback Device for Parkinson’s Patients
Joseph Krigbaum,
Joseph Krigbaum
Arizona State University, Tempe, AZ
Search for other works by this author on:
Alvaro Rascon,
Alvaro Rascon
Arizona State University, Tempe, AZ
Search for other works by this author on:
Harsh Patil,
Harsh Patil
Arizona State University, Tempe, AZ
Search for other works by this author on:
Shannon Jameson,
Shannon Jameson
St. Joseph’s Hospital and Medical Center, Phoenix, AZ
Search for other works by this author on:
Panagiotis Polygerinos
Panagiotis Polygerinos
Arizona State University, Mesa, AZ
Search for other works by this author on:
Joseph Krigbaum
Arizona State University, Tempe, AZ
Alvaro Rascon
Arizona State University, Tempe, AZ
Harsh Patil
Arizona State University, Tempe, AZ
Shannon Jameson
St. Joseph’s Hospital and Medical Center, Phoenix, AZ
Panagiotis Polygerinos
Arizona State University, Mesa, AZ
Paper No:
DMD2019-3207, V001T09A003; 4 pages
Published Online:
July 19, 2019
Citation
Krigbaum, J, Rascon, A, Patil, H, Jameson, S, & Polygerinos, P. "Haptic Neurofeedback Device for Parkinson’s Patients." Proceedings of the 2019 Design of Medical Devices Conference. 2019 Design of Medical Devices Conference. Minneapolis, Minnesota, USA. April 15–18, 2019. V001T09A003. ASME. https://doi.org/10.1115/DMD2019-3207
Download citation file:
566
Views
Related Proceedings Papers
Related Articles
Miniaturized Cutting Tool With Triaxial Force Sensing Capabilities for Minimally Invasive Surgery
J. Med. Devices (September,2007)
Soft Actuating Sit-to-Stand Trainer Seat
J. Mechanisms Robotics (February,2019)
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
Related Chapters
A New Mobile Haptic Game for Dynamic Objects
International Conference on Software Technology and Engineering (ICSTE 2012)
Norms of Feedback Systems
Robust Control: Youla Parameterization Approach
Comparison of the Availability of Trip Systems for Reactors with Exothermal Reactions (PSAM-0361)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)