A successful spinal implant design requires that it perform consistently under a known set of loading conditions. Specifically, the loading conditions experienced in the activities of everyday living must be accounted for in both the design and testing of spinal arthrodesis implants. Knowledge of these loading conditions and, in particular, those which produce implant failure, must be addressed continuously during the design, testing and even during the actual clinical use of the implant. The goals of this presentation are: 1) to provide an understanding of typical spinal implant test procedures and, 2) to understand how to utilize real world failure data to optimize the test loading conditions which would predict failure of a spinal implant. For the first goal, ASTM standards for testing of spinal implants will be described and, for the second goal, data from a clinical case with failure of a pedicle screw connector will be utilized. This will include data from the patient’s medical records, structural and material properties of the implant material, and accident reconstruction analyses. The combined data will provide a most probable cause of implant failure and failure load.
Skip Nav Destination
ASME 2010 5th Frontiers in Biomedical Devices Conference
September 20–21, 2010
Newport Beach, California, USA
Conference Sponsors:
- Nanotechnology Institute
ISBN:
978-0-7918-4945-3
PROCEEDINGS PAPER
Evaluation of Spinal Arthrodesis Implant Designs: A Biomedicial-Legal Perspective
Mark A. Gomez,
Mark A. Gomez
University of California, San Diego, La Jolla, CA
Search for other works by this author on:
J. Marcus Hollis
J. Marcus Hollis
Blue Bay Research Inc., Navarre, FL
Search for other works by this author on:
Mark A. Gomez
University of California, San Diego, La Jolla, CA
J. Marcus Hollis
Blue Bay Research Inc., Navarre, FL
Paper No:
BioMed2010-32080, pp. 21-22; 2 pages
Published Online:
July 16, 2013
Citation
Gomez, MA, & Hollis, JM. "Evaluation of Spinal Arthrodesis Implant Designs: A Biomedicial-Legal Perspective." Proceedings of the ASME 2010 5th Frontiers in Biomedical Devices Conference. ASME 2010 5th Frontiers in Biomedical Devices Conference and Exhibition. Newport Beach, California, USA. September 20–21, 2010. pp. 21-22. ASME. https://doi.org/10.1115/BioMed2010-32080
Download citation file:
5
Views
Related Proceedings Papers
Related Articles
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
A Protocol to Evaluate Semi-Rigid Pedicle Screw Systems
J Biomech Eng (August,1997)
A Pseudo-Rigid-Body Model of the Human Spine to Predict Implant-Induced Changes on Motion
J. Mechanisms Robotics (November,2011)
Related Chapters
Introduction
Design of Hazardous Mechanical Structures, Systems and Components for Extreme Loads
Estimating Resilient Modulus Using Neural Network Models
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Development and Structure of the German Common Cause Failure Data Pool (PSAM-0020)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)