Pedicle screws are commonly used in spine surgery to implant and affix metal devices to the spine. These screws are most commonly associated with cases that require rod or plate implantation. Use of pedicle screws in osteoporotic patients, however, is limited because they suffer from low bone mass density (BMD). The low BMD is harmful to patients in two ways — it leads to increased incidence of spinal trauma and also prevents surgeons from instrumenting osteoporotic patients because screws do not achieve the required fixation in osteoporotic patients [1]. The risk of trauma is increased due to the brittle bone and vertebral compression fractures, resulting in spinal misalignment and increased risk of future trauma. Instrumenting these cases with rods or plates, however, is impossible because osteoporotic bone is not strong enough to “hold” pedicle screws in, i.e., prevent screws from pulling out [2, 3].
Skip Nav Destination
ASME 2007 2nd Frontiers in Biomedical Devices Conference
June 7–8, 2007
Irvine, California, USA
Conference Sponsors:
- Nanotechnology Institute
ISBN:
0-7918-4266-5
PROCEEDINGS PAPER
A Pull-Out Resistant Pedicle Screw for the Osteoporotic Spine
Karthik Ponnusamy,
Karthik Ponnusamy
Johns Hopkins University, Baltimore, MD
Search for other works by this author on:
Sravisht Iyer,
Sravisht Iyer
Johns Hopkins University, Baltimore, MD
Search for other works by this author on:
Alex Hui,
Alex Hui
Johns Hopkins University, Baltimore, MD
Search for other works by this author on:
Gaurav Gupta,
Gaurav Gupta
Johns Hopkins University, Baltimore, MD
Search for other works by this author on:
Kartik Trehan,
Kartik Trehan
Johns Hopkins University, Baltimore, MD
Search for other works by this author on:
Christopher Yu,
Christopher Yu
Johns Hopkins University, Baltimore, MD
Search for other works by this author on:
A. Jay Khanna
A. Jay Khanna
Johns Hopkins Orthopaedics at Good Samaritan, Baltimore, MD
Search for other works by this author on:
Karthik Ponnusamy
Johns Hopkins University, Baltimore, MD
Sravisht Iyer
Johns Hopkins University, Baltimore, MD
Alex Hui
Johns Hopkins University, Baltimore, MD
Gaurav Gupta
Johns Hopkins University, Baltimore, MD
Kartik Trehan
Johns Hopkins University, Baltimore, MD
Christopher Yu
Johns Hopkins University, Baltimore, MD
A. Jay Khanna
Johns Hopkins Orthopaedics at Good Samaritan, Baltimore, MD
Paper No:
BioMed2007-38050, pp. 115-116; 2 pages
Published Online:
February 24, 2009
Citation
Ponnusamy, K, Iyer, S, Hui, A, Gupta, G, Trehan, K, Yu, C, & Khanna, AJ. "A Pull-Out Resistant Pedicle Screw for the Osteoporotic Spine." Proceedings of the ASME 2007 2nd Frontiers in Biomedical Devices Conference. ASME 2007 2nd Frontiers in Biomedical Devices. Irvine, California, USA. June 7–8, 2007. pp. 115-116. ASME. https://doi.org/10.1115/BioMed2007-38050
Download citation file:
4
Views
Related Proceedings Papers
Related Articles
Factors Affecting the Pullout Strength of Cancellous Bone Screws
J Biomech Eng (August,1996)
Novel re-entrant porous composite structure: a potential for orthopaedic applications
J. Med. Devices (June,2008)
Comparison of Posterior Fixation Strategies for Thoracolumbar Burst Fracture: A Finite Element Study
J Biomech Eng (July,2021)
Related Chapters
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
Fatigue Analysis in the Connecting Rod of MF285 Tractor by Finite Element Method
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)
Insights and Results of the Shutdown PSA for a German SWR 69 Type Reactor (PSAM-0028)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)