In the refrigeration and air conditioning fields, the needs of energy conservation and renewable energy spread have become stronger recently. In this study, we aim at the development of the heat driven type metal hydride (abbr, MH) that can be driven by the low temperature exhausted heat or solar heat under 100°C. In order to commercialize this system, the heat transfer characteristics and the activation characteristics of MH particle bed must be more improved, and production cost must be more reduced. In this study, we use the two heat transfer enhancement methods for improving the low effective thermal conductivity of MH particle bed. One is by heat pipe (abbr., HP) and another is by brush type carbon fiber. HP is inserted into heat source part MH (abbr., MH1). By this method, we aim not only to enhance the heat transfer of MH1 particle bed but also to achieve the temperature uniformity of MH1 particle one. The effective thermal conductivity of cooling part MH (abbr., MH2) particle bed is enhanced by inserting the brush type carbon fiber. The influence of these heat transfer methods on our MH refrigeration system is estimated by measurement and calculation.
Skip Nav Destination
ASME/JSME 2011 8th Thermal Engineering Joint Conference
March 13–17, 2011
Honolulu, Hawaii, USA
Conference Sponsors:
- Heat Transfer Division
ISBN:
978-0-7918-3892-1
PROCEEDINGS PAPER
Influence of Inserting the Heat Pipe Into the MH Particle Bed on Refrigeration Performance
Sangchul Bae,
Sangchul Bae
Waseda University, Saitama, Japan
Search for other works by this author on:
Keisuke Ishikawa,
Keisuke Ishikawa
Waseda University, Tokyo, Japan
Search for other works by this author on:
Yusuke Haruna,
Yusuke Haruna
Waseda University, Tokyo, Japan
Search for other works by this author on:
Masafumi Katsuta
Masafumi Katsuta
Waseda University, Tokyo, Japan
Search for other works by this author on:
Sangchul Bae
Waseda University, Saitama, Japan
Eiji Morita
Waseda University, Tokyo, Japan
Keisuke Ishikawa
Waseda University, Tokyo, Japan
Yusuke Haruna
Waseda University, Tokyo, Japan
Masafumi Katsuta
Waseda University, Tokyo, Japan
Paper No:
AJTEC2011-44215, T20003; 8 pages
Published Online:
March 1, 2011
Citation
Bae, S, Morita, E, Ishikawa, K, Haruna, Y, & Katsuta, M. "Influence of Inserting the Heat Pipe Into the MH Particle Bed on Refrigeration Performance." Proceedings of the ASME/JSME 2011 8th Thermal Engineering Joint Conference. ASME/JSME 2011 8th Thermal Engineering Joint Conference. Honolulu, Hawaii, USA. March 13–17, 2011. T20003. ASME. https://doi.org/10.1115/AJTEC2011-44215
Download citation file:
7
Views
Related Proceedings Papers
Efficient Concept of Low Energy Building
IMECE2005
Related Articles
Novel Combined Power and Cooling Thermodynamic Cycle for Low Temperature Heat Sources, Part I: Theoretical Investigation
J. Sol. Energy Eng (May,2003)
A Liquid Desiccant System for Solar Cooling and Dehumidification
J. Sol. Energy Eng (August,2004)
Solar Heat Underground Storage Based Air Conditioning Vis-à-Vis Conventional HVAC Experimental Validation
J. Sol. Energy Eng (February,2018)
Related Chapters
Integration of Solar Energy Systems
Handbook of Integrated and Sustainable Buildings Equipment and Systems, Volume I: Energy Systems
Two-Stage Liquid Desiccant Dehumidification∕Regeneration
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Numerical Simulation and Analysis about Harmonic Performance Used for Heat Transfer and Air-Conditioning Cooling Load of Energy-Saving Porous Brick and Hollow Brick Wall
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)